Johnson Power Systems - Irrigation Control Panel
When in the Hand Mode the motor will start
When in the Auto Mode the motor will start with 120 volt from pivot panel.
When in the Auto-PSI Mode the speed dial on the front of the VFD will operate as a pressure set point - setable from 0 to 100 PSI.
When in the Manual-RPM Mode the speed dial on the front of the VFD will operate as a RPM setpoint - set from 0 -100%.
Standard Options
VFD
Line Reactor
Enclosure: 53" x 36" x 16" (with top vent)
Main Line Circuit Breaker
Handle
Wiring Terminal Lugs
250VA Control Transformer
Control Relay (base) - 120 Volt
Control Relay (socket)
Lightening Surge Supressor
Pressure Transducer: 0-100 PSI
Breaker: 480v - 1 amp / 2 pole
1 x 3 Position Selector Switch (Hand-Off-Auto)
2 x 2 Position Selector Switch (Speed Control - Auto/Manual)
3 - NO Contact Block
1 - NC Contact Block
Speed Potentiometer: 5K OHM (Auto=PSI / Manual=RPM)
GFCI Service Outlet (15 amp breaker built-in)
Neutral Bar - electrical
Service Enterance Grounding Lugs
UL/ETL Listed
Labor Included (Assembly/programming/testing)
​
​
​